Got Questions?
Please call Toll Free (877) 276-1084
for a product price quote
or Send us an E-mail

Search

Our Newsletter


Vapors released into the workplace during the printing process are capable of producing a number of unpleasant human reactions. Purex Large Format Printing Fume Extractors will eliminate these hazardous fumes and help deliver actual savings to the production process.


Description: Fumes are produced by wide format printersInk fumes from printers can cause headaches and nausea but also an unpleasant working environment and so they should be controlled. Processes requiring fume extraction include:

  • Wide Format Printers
  • Dye Sublimation
  • UV Printing
  • and more...

Purex systems are available with bespoke connection kits for all common printer models including:

  • EFI Vutek
  • HP
  • Mimaki
  • Mutoh
  • Roland
  • OCE
  • Seiko
  • and more...

The Solution

Description: Captivair extractor on a wide format printerOur fume extraction systems are designed in conjunction with some of the worlds largest printer manufactures.
There are typically three sources of fumes and odours when using a wide format printer: -

1.    Vapor released as the ink is applied
2.    Vapor from the print passing over the heater platen
3.    Vents underneath the heater platen

The Captivair includes hoods, hoses and manifolds to capture fumes from the printer's enclosure at several key points. The contaminated air is then drawn through a special filter where the contaminants are captured allowing filtered air to be returned to the workplace.
After initial consultation Purex engineers can visit a site free of charge to carry out a survey* and to suggest suitable designs and solutions. What to do next: -

Machine Selection Guide

Make Model Captivair™ Extractor
EFI Vutek Ultra Vu 260 CaptivairMAX
HP DesignJet 8000s/9000s
DesignJet 10000s
Mimaki JV3-250SPF
JV3-130 CaptivairMINI
JV3-160 CaptivairMAX
JV5-160S
JV5-320S
JV33-130SP CaptivairMINI
JV33-160SP
CJV30-100
CJV30-130
CJV30-160
Mutoh 64" Tucan LT CaptivairMAX
PJ Series 1.9m
Roland Versa UV LEC300 Call for more information
AdvancedJet AJ-740 CaptivairMAX
AdvancedJet AJ-1000
Oce CS6060
Seiko Colourpainter V-64s
Colourpainter H-74s
Colourpainter H-104s

Machine Selection Guide

               
Codes Per Minute (CPM)
200i

400i

800i
High Dust

800i
High Gas

1500i

2000i

5000i
Good Enclosure Poor Enclosure
<200   - - - - -
  <200 X - - - -
200-500   X - - - -
  200-500 X X - - -
>500   X X - - -
  >500 X X X X -
Machines for lasing PVC X O X X X X X

Key:
Normal selection.
Select if extra filter capacity is required and/or additional airflow is required to extract from multiple lasers or heavy duty applications.
(-) May also be considered.
X  Unit not usually specified for application.
O For lasing onto PVC.

Notes:
1. The selection is based on the use of standard connection kit.
2. The 800i 3 tier unit is designed for use where the application has low dust, but high gas emissions. The 2 tier is designed for applications producing high dust emissions.
3.  A poor enclosure is where less than 4 sides of the process are enclosed.